Catalog Page
Imagen
Imagen
Dixon Distributor?
Log in to view pricing, inventory, place orders & much more. If you want to create an account, please click the button to begin the registration process.
Atributos
Weight |
0.09 lb
|
---|---|
Break Quantity |
1
|
Paquete Opcional/Cantidad por Caja |
1
|
Material |
Acero
|
Maximum OD |
|
Thread |
BSPP
|
Body Size |
|
Temperature Range |
6" grooved manifold with six 2" female NT ports, one 1" NPT port (left or right version)°F (Not pressure retaining, open flow only°C)
|
Thread Size |
|
Length |
|
Hex |
|
Pressure Rating |
Detalles
Compatibilidad e Intercambio de Datos
- Foster 3, 4, 5 and 6 Series
- Parker 30 - Series Automatic Interchange & Parker 20-Series Manual Interchange
- Hansen 3000, 4000, 5000 and 6000 & Hansen 1000, 400 and 500
Construcción
- Machined components are manufactured using solid bar stock.
- Steel componentry is plated using ROHS Compliant Trivalent Chrome.
Como funciona
- To disconnect, begin by holding the hose on the nipple side with three of your fingers, leaving your thumb and index finger free.
- Grab the sleeve with your thumb and index finger and begin to pull the sleeve towards the palm of your hand.
- After pulling the sleeve, the nipple will move out of the coupler slightly. Continue to hold the hose and coupler sleeve until all air is fully exhausted.
- After the line is fully exhausted, you are able to safely separate the nipple from the coupler.
Notas de Seguridad
It is important to be safe when installing quick disconnect couplings into a pneumatic circuit. Never install a pneumatic coupling directly into an air tool, use a piece of hose that is at least 18" long, between the tool and the coupling, to prevent damage to the coupling. To protect the operator, safety devices, such as a safety check valve and safety cable should be installed in case there is a hose or coupling failure.
Especificaciones
- Rated pressure when connected with Brass D-Series Automatic Couplers: 500 PSI (35 bar) Maximum Working and 15,500 PSI (1,070 bar) Burst
- Rated pressure when connected with Brass F-Series Manual Couplers: 500 PSI (35 bar) Maximum Working and 11,500 PSI (790 bar) Burst
- Rated pressure when connected with Steel F-Series Manual Couplers: 500 PSI (35 bar) Maximum Working and 19,500 PSI (1,345 bar) Burst
Recursos
Imagen
Learning Video
Imagen
Learning Video
Imagen
Product Literature