Image
L28 series filter

L28-04AMB - Wilkerson FRLs L28-Series EconOmist® Standard Lubricator

Dixon Distributor? 

Log in to view pricing, inventory, place orders & much more. If you want to create an account, please click the button to begin the registration process.

Attributes

Maximum Operating Pressure Metric
17.2 Bar
Maximum Operating Pressure
250 PSIG
Weight
1.7 lb
Break Quantity
0
Optional Package/Box Quantity
0
Temperature Range
14°F to 150°F (-10°C to 65.5°C)
Flow
110 SCFM
Port
1/2"

Details

Description

Metal Bowl

Features

  • 6 oz. bowl
  • Metal Bowl
  • Manual drain
  • High flow capacity

Safety Notes

  • FRL's are designed for air service only, unless otherwise indicated.
  • SCFM ratings at 150 PSIG inlet pressure

Use

  • To adjust and set oil delivery rate the unit must be pressurized and air must be flowing through the unit. Turn the sight dome, located on the top of the unit, counter clockwise to initiate oil delivery. If flow increases or decreases, the oil delivery rate will increase or decrease proportionally. Turning the sight dome clockwise will stop oil delivery.
  • Can be filled under pressure
  • For all Wilkerson lubricators, use any petroleum-base, non-detergent light weight oil (SAE 10/150 SSU) which will readily break up into a mist, i.e., Mobil DTE light or comparable oil. Do not use any synthetic oil or oils containing additives or solvents.

Resources

    Request a Quote

    Need help selecting the correct components?