Attributes
Optional Package/Box Quantity |
1
|
---|---|
Service Test Pressure Metric |
1035 kPa
|
Size |
Standard
100kg
|
Material |
Mild Steel
|
Temperature Rating Metric | |
Mount |
Self Standing (frame)
|
Style |
Single Remote Actuated Loading Valve Control Operation
|
Fitting Type |
Flanged Head
|
Working Pressure |
345 kPa
|
Height |
1760 mm
|
Details
Applications
Designed for loading prilled ammonium nitrate/fuel oil (ANFO) in varying diameter drill holes, both in horizontal and vertical positions.
Features
- Flanged opening on head allows for on-site servicing of internal sealing cone. Selaing cone is replaceable.
- Comes with Lid and Trash Screen to aid breaking of ANFO and prevent foreign objects from entering the unit when not in use.
Includes
Lid and Trash Screen
Note
Purchasers of anfo loaders are supplied with a copy of the Manufacturers Data Report - Pressure Vessel at point of delivery.
Safety Notes
- To comply with AS1210 SAA Unfired Pressure Vessels Code, the vessel must not be used for transport of material under pressure.
- Purchasers are advised that the Anfo Loader (Pressure Vessel) manufactured under AS1200 is subject to Occupational Health, Safety and Welfare Regulations, 1995 (page 5 section 3.2.24(1)(a)). An employer must ensure that pressure equipment, other than a gas cylinder thatis covered by AS1200 SAA Boiler Code and that is in USE, is inspected or tested in accordance with AS3788.
- Purchasers should refer to Australian Standards AS3788 - Pressure Equipment In-Service Inspection, Section 3: Inspection Personnel and Administration; Section 4: Pressure Equipment Inspection.
Specifications
- Volume: 146 L
- Actual Ango Capacity: 117kg
- Designed and manufactured in accordance with AS1210 - 1989 - Class 3
Use
After the loader has been filled to capacity, it is pressurised by compressed air to the pre-determined discharge pressure, thus the rate of discharge can be varied to obtain the required density and charge rate.